Highly portable air heaters Dual voltage · Functions on propane gas. Gas regulator, fully adjustable to required output · Equipped with safely thermostat & cutout device.
Ideal for heating well ventilated workshops and drying in building sites.
Highly portable air heaters · Dual voltage · Functions on propane gas.
Gas regulator, fully adjustable to required Output · Equipped with safely thermostat & cutout device.
Ideal for heating well ventilated workshops and drying in building sites.
TIP! Two smaller heaters will often heat an erea more efficiently than one large heater. |
 |
 |
 |
 |
| Part Number |
13amp |
G10 |
G30 |
G40 |
G60 |
G100 |
| Heat Output |
BTU/Hr |
35,000 |
41,000-106,000 |
91,000-148,000 |
119,000-200,000 |
200,000-344,000 |
| 13 -amp -supply |
Kw |
10 |
12-31 |
27-44 |
35-58 |
58-1000 |
| Hot Air Flow |
M3/Hr |
300 |
750 |
850 |
1800 |
3300 |
| Gas Pressure |
Bar |
0.3 |
1.5 |
2.0 |
2.0 |
2.0 |
| Fuel |
Type |
Propane |
Propane |
Propane |
Propane |
Propane |
| Fuel Comsumption |
Kg/Hr |
0.78 |
0.98-2.46 |
2.10-3.43 |
2.75-4.61 |
4.5-7.9 |
| Mains Input |
Volts |
230 |
230/110 |
230/110 |
230/110 |
230/110 |
| Dimensions |
mm |
180x390x270 |
280x530x400 |
280x690x400 |
370x780x520 |
1060x424x562 |
| Weight |
Kg |
5 |
11.5 |
13 |
20 |
28 |
| Minimum Cylinders |
_____ |
1 or 2x13kg |
1 or 2x13kg |
1x47kg or 2x19kg |
1 or 2x47kg |
2x47kg |
|
· Spark plug ignition for easy starting · Pneumatic atomising burner · Stainless steel combustion chamber. · Photoelectric flame sensor · Functions on paraffin or diesel · Automatic electric safely and control device . · Portable, put the heat where you need it. · Ideal for heating well ventilated premises and drying in building sites.
FUEL SELECTION The correct grade is 35 second diesel oil. . Do not use waste oil or domestic heating fuels.
. The correct grade is 28 second kerosene, (paraffin) which is clear in colour.
SAFETY : Ventilation of the area is necessary to prevent a deficiency of the oxygen supply. |
 |
 |
| Part Number |
____ |
D15 |
D20 |
D28 |
D40 |
| Heat Output |
BTU/Hr |
51,000 |
80,000 |
100,000 |
148,000 |
| 13 -amp -supply |
Kw |
15 |
23 |
28 |
43 |
| Hot Air Flow |
M3/Hr |
350 |
400 |
500 |
1050 |
| Motor |
Watt |
100 |
100 |
150 |
250 |
| Fuel |
Type |
Paraffin or Diesel |
Paraffin or Diesel |
Paraffin or Diesel |
Paraffin or Diesel |
| Fuel Comsumption |
Ltr/Hr |
1.48 |
2.31 |
2.78 |
4.25 |
| Tank Size |
Litres |
11 |
21 |
30 |
46 |
| Mains Input |
Volts |
230 |
230 |
230 |
230 |
| Dimensions |
mm |
800x355x345 |
830x430x465 |
860x485x530 |
930x560x615 |
| Weight |
Kg |
16 |
26 |
31 |
37 |
|
INDIRECT FIRED OIL HEATERS |
· High output models with flue tube · Clean heat & high efficiency. · Stainless steel combustion chamber with automatic cooling.
· 230 Volt single phase Long run diesel tanks · Overheat and flame sensor protection · Full automatic operation with optional room thermostat.
· Housing remains cool to touch · Wheel mounted for portability · Ideal for workshop heating & drying in building sites.
· Optional 6 metre flexible duding for sites marquees etc (Models 1D36153/84) |
 |
 |
| Part Number |
___ |
ID26 |
ID36 |
ID53 |
ID84 |
| Heat Output |
BTU/Hr |
90,000 |
125,000 |
180,000 |
289,000 |
| 13 -amp -supply |
Kw |
26 |
36 |
53 |
84 |
| Hot Air Flow |
M3/Hr |
1100 |
2000 |
2500 |
4500 |
| Thermal Efficiency |
% |
80 |
87 |
87 |
89 |
| Fuel |
Type |
Paraffin or Diesel |
Diesel |
Diesel |
Diesel |
| Fuel Comsumption |
Ltr/Hr |
2.2 |
3.35 |
4.84 |
7.72 |
| Tank Size |
Litres |
46 |
51 |
51 |
100 |
| Mains Input |
Volts |
230 |
230 |
230 |
230 |
| Safety Cutout |
Photocell |
Standard |
Standard |
Standard |
Standard |
| Flue Diameter |
mm |
150 |
150 |
150 |
150 |
| Hot Air Outlet Dia- |
mm |
|
308 |
308 |
443 |
| Dimensions |
mm |
930x560x625 |
1188x620x790 |
1188x620x790 |
1680x690x938 |
| Weight |
Kg |
43 |
70 |
76 |
121 |
|
· High output model · Clean heat & high efficiency. · Stainless steel combustion chamber with automatic cooling. · 230 Volt single phase · Operates on paraffin or diesel fuel · Long run fuel tank. · Overheat and flame sensor protection · Full automatic operation with optional room thermostat. · Housing remains cool to touch · Wheel mounted for portability · Ideal for large volume workshop heating.
SAFETY: Ventilation of the area is necessary to prevent deficiency of the oxygen supply |
| Part Number |
D115 |
| Heat Output: BTU/Hr |
400.000 |
|
115 |
| Hot Air Flow: Ms/Hr |
4000 |
| Fuel Type |
Paraffin or Diesel |
| Fuel Consumption: Litres |
11.0 |
| Tank Size: Litres |
80 |
| Mains Input: Volts |
230 |
| Safety Cutout: Photocell |
Standard |
| Dimensions: mm |
1600x660x1000 |
| Weight: Kg |
95 |
|
Contact Information
If you would like more information on any of the machines featured on this Website, or if a particular machine is available for hire, then please contact us by phone, fax or email.
Independent Welding Services Ltd Unit 2 15 Douglas Road Kingswood Bristol. BS15 8NH United Kingdom
Tel: +44 0117 9352540 Fax: +44 0117 9352627

e-mail: info@indeweld.com
subject to stock availability
You should receive a timely response with 24 hours. |
|